WEKO3
アイテム
{"_buckets": {"deposit": "1f546879-58a4-4ecc-a9c5-2a37d09eae7d"}, "_deposit": {"created_by": 4, "id": "803", "owners": [4], "pid": {"revision_id": 0, "type": "depid", "value": "803"}, "status": "published"}, "_oai": {"id": "oai:nagoya-wu.repo.nii.ac.jp:00000803", "sets": ["80"]}, "author_link": ["4948", "4947"], "item_1_alternative_title_5": {"attribute_name": "論文名よみ", "attribute_value_mlt": [{"subitem_alternative_title": "Studies on Central Cleaning System (Part 4) : Design of Cyclone Gate"}]}, "item_1_biblio_info_14": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "1973-03-15", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "145", "bibliographicPageStart": "139", "bibliographicVolumeNumber": "19", "bibliographic_titles": [{"bibliographic_title": "名古屋女子大学紀要"}, {"bibliographic_title": "Journal of the Nagoya Women\u0027s College", "bibliographic_titleLang": "en"}]}]}, "item_1_creator_8": {"attribute_name": "著者名(英)", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Mori, Kunio", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "4947", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Matsuyama, Masahiko", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "4948", "nameIdentifierScheme": "WEKO"}]}]}, "item_1_description_1": {"attribute_name": "ページ属性", "attribute_value_mlt": [{"subitem_description": "P(論文)", "subitem_description_type": "Other"}]}, "item_1_description_12": {"attribute_name": "抄録(英)", "attribute_value_mlt": [{"subitem_description": "\"A simplicity mechanism which some un-uniform dust are vomited automatically, was designed and manufactured by way of trial. The height of cyclone is designed less the dust should be pile over the entrance of cyclone, that is, in the equation (1), the height H must be greater than h when R=0. (1) As the specific gravity is very great in the case of rices, the volume of rices excluded at a time is small enough, and the height of cyclone H may be designed small. (2) When we transport dusts of which specific gravity is small, the negative pressure q or Q in the cyclone is so great and the volume of the dust excluded at a time is so great that the hight of the cyclone H must be designed to be very great. Even if the electromagnet is not used, or in the case of F=0, when the dust of regular weight is piled up in the cyclone, the gate of cyclone is opened speedily and the dust is excluded completly. Even if dusts of the constant volume are not piled, when we finish the cleaning, and when the blower is stopped, Q is equal to zero. And if the weight is set on the position of S=Wl_w + W_al_1 - W_ll≒Q, even a few dusts can be excluded, the cyclone is prepared for the next cleaning.\"", "subitem_description_type": "Other"}]}, "item_1_source_id_13": {"attribute_name": "雑誌書誌ID", "attribute_value_mlt": [{"subitem_source_identifier": "AN00179986", "subitem_source_identifier_type": "NCID"}]}, "item_1_text_10": {"attribute_name": "著者所属(英)", "attribute_value_mlt": [{"subitem_text_language": "en", "subitem_text_value": "NAGOYA WOMEN\u0027S COLLEGE"}, {"subitem_text_language": "en", "subitem_text_value": "NAGOYA WOMEN\u0027S COLLEGE"}]}, "item_1_text_2": {"attribute_name": "記事種別(日)", "attribute_value_mlt": [{"subitem_text_value": "論文"}]}, "item_1_text_9": {"attribute_name": "著者所属(日)", "attribute_value_mlt": [{"subitem_text_value": "名古屋女子大学"}, {"subitem_text_value": "名古屋女子大学"}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "1973-03-15"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "KJ00000727092.pdf", "filesize": [{"value": "428.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensefree": "BY-NC-ND", "licensetype": "license_free", "mimetype": "application/pdf", "size": 428100.0, "url": {"label": "KJ00000727092", "url": "https://nagoya-wu.repo.nii.ac.jp/record/803/files/KJ00000727092.pdf"}, "version_id": "2a592537-dad2-4f41-ae11-52a2036e38ad"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "departmental bulletin paper", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Studies on Central Cleaning System (Part 4) : Design of Cyclone Gate", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Studies on Central Cleaning System (Part 4) : Design of Cyclone Gate", "subitem_title_language": "en"}]}, "item_type_id": "1", "owner": "4", "path": ["80"], "permalink_uri": "https://nagoya-wu.repo.nii.ac.jp/records/803", "pubdate": {"attribute_name": "公開日", "attribute_value": "1973-03-15"}, "publish_date": "1973-03-15", "publish_status": "0", "recid": "803", "relation": {}, "relation_version_is_last": true, "title": ["Studies on Central Cleaning System (Part 4) : Design of Cyclone Gate"], "weko_shared_id": 4}
Studies on Central Cleaning System (Part 4) : Design of Cyclone Gate
https://nagoya-wu.repo.nii.ac.jp/records/803
https://nagoya-wu.repo.nii.ac.jp/records/803c08483c2-cf1f-49b7-ba88-d0d6e7d29a6f
名前 / ファイル | ライセンス | アクション |
---|---|---|
KJ00000727092 (428.1 kB)
|
BY-NC-ND
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 1973-03-15 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | Studies on Central Cleaning System (Part 4) : Design of Cyclone Gate | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
記事種別(日) | ||||||
論文 | ||||||
論文名よみ | ||||||
その他のタイトル | Studies on Central Cleaning System (Part 4) : Design of Cyclone Gate | |||||
著者名(英) |
Mori, Kunio
× Mori, Kunio× Matsuyama, Masahiko |
|||||
著者所属(日) | ||||||
名古屋女子大学 | ||||||
著者所属(日) | ||||||
名古屋女子大学 | ||||||
著者所属(英) | ||||||
en | ||||||
NAGOYA WOMEN'S COLLEGE | ||||||
著者所属(英) | ||||||
en | ||||||
NAGOYA WOMEN'S COLLEGE | ||||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | "A simplicity mechanism which some un-uniform dust are vomited automatically, was designed and manufactured by way of trial. The height of cyclone is designed less the dust should be pile over the entrance of cyclone, that is, in the equation (1), the height H must be greater than h when R=0. (1) As the specific gravity is very great in the case of rices, the volume of rices excluded at a time is small enough, and the height of cyclone H may be designed small. (2) When we transport dusts of which specific gravity is small, the negative pressure q or Q in the cyclone is so great and the volume of the dust excluded at a time is so great that the hight of the cyclone H must be designed to be very great. Even if the electromagnet is not used, or in the case of F=0, when the dust of regular weight is piled up in the cyclone, the gate of cyclone is opened speedily and the dust is excluded completly. Even if dusts of the constant volume are not piled, when we finish the cleaning, and when the blower is stopped, Q is equal to zero. And if the weight is set on the position of S=Wl_w + W_al_1 - W_ll≒Q, even a few dusts can be excluded, the cyclone is prepared for the next cleaning." | |||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00179986 | |||||
書誌情報 |
名古屋女子大学紀要 en : Journal of the Nagoya Women's College 巻 19, p. 139-145, 発行日 1973-03-15 |